Pdf package insert for d-dimer

Manufacturers were encouraged to contact their clients to promote the use of only the type and magnitude of ddimer units provided in the package insert. For additional information, refer to the alere triage meter user manual. D dimer latex agglutination kit diagnostic reagent for the rapid qualitative or semiquantitative evaluation of circulating derivates of crosslinked fibrin degradation products xlfdp in human plasma t9515707 1 x 2,7 ml d dimer latex 1 x 25 ml d dimer buffer 1 x 0,5 ml positive control 1 x 0,5 ml negative control 5 pcs. The degree of agglutination is directly proportional to the concentration of ddimer in the sample and is determined by measuring the decrease of transmitted light caused by the aggregates turbidimetric immunoassay. Nycocard ddimer measures ddimer configurated molecules, which are released into the circulation by the activation of the fibrinolysis system. Ddimer is a specific marker of degradation of fibrin clot and an indirect marker of clot formation.

Eleven single doses of tretten have been administered to nine subjects for pharmacokinetic investigations. Each unique istat system cartridge contains chemically sensitive biosensors on a silicon chip that are. To share the full product catalog, please use the product catalog download option from the navigation bar at the top of the page. The ddimer values are presented in units of mass ngml of ddimer, also known as ddimer units ddu. Standard test mode according to the analyzers manual.

By definition, one feu is the quantity of fibrinogen initially present that leads to the observed level of ddimer. Ddimer levels are expressed in initial fibrinogen equivalent unitsfeu. Refer to figure 1 and the package insert for detail intended use bioway chemistry reagent series ddimer reagent kit the kit is a latexenhanced immunoturbidimetric assay intended for in vitro quantitative detection of ddimer protein in human serum or. High levels of ddimer are commonly associated with complications in pregnancy.

Ddimer is a soluble degradation product of crosslinked fibrin under the action of the fibrinolytic system. Testkit for quantitative determination of ddimer in plasma on smart photometer. The axsym d dimer reagents and sample are pipetted in the following sequence. The d dimer values are presented in units of mass ngml of d dimer, also known as d dimer units d du. Refer to package insert for complete instrument listing. Treatment day gamifant dose criteria for dose increase if abnormal at baseline and no. Widely used types and clinical applications of ddimer assay. Refer to figure 1 and the package insert for detail intended use bioway chemistry reagent series ddimer reagent kit the kit is a latexenhanced immunoturbidimetric assay intended for in vitro quantitative detection of ddimer protein in human serum or plasma on automated clinical chemistry analyzers. Carry out semiquantitative detection of fibrin and fibrinogen degradation products in human serum and urine using thermo scientific thrombowellcotest rapid latex agglutination test. Ddimer is a reliable and sensitive index of fibrin deposition and stabilization. Liquichek ddimer control clinical diagnostics biorad.

A plasma ddimer test is commonly the first step in patient apte risk assessment, and is considered to have clinical value 15. Roche cobas h 232 ddimer method and sample collection iecdd. Implementation of a rapid whole blood ddimer test in the emergency department of an urban academic medical center. Coagulopathy both ddimer and fibrinogen must apply ddimer from day 6 onwards increase to 6 mgkg reference id. D dimer from day 6 onwards increase to 6 mgkg reference id. The stratus cs ddimer assay is intended for use in conjunction with a nonhigh clinical pretest probability ptp assessment model to exclude pulmonary embolism pe disease and as an aid. Provide content correction we continue to work to improve your shopping experience and your feedback regarding this content is very important to us.

Pdf evaluation of the innovance ddimer analytical performance. To demonstrate reliable clinical performance and compliance with the rigorous requirements of clsi h59a. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert. Alere triage ddimer test product insert pi, english. Apr 28, 2017 a plasma ddimer test is commonly the first step in patient apte risk assessment, and is considered to have clinical value 15. Suggest ddimer 4 and package insert highlights clinical validation studies for pe and vte, but not dic. Stago detail staliatest ddi plus, less interferences.

Target level ddimer ngml feu level low 250 level 1 550 level 2 1600 level 3 3200 the values listed are approximate targets. Noninvasive diagnosis of venous thromboembolism in outpatients. Treatment day gamifant dose criteria for dose increase if abnormal at baseline and no improvement fibrinogen mgdl if baseline levels. The innovance ddimer method, like the vidas ddimer exclusiontm method, is intended for use in conjunction with a clinical pretest probability ptp assessment model to exclude pulmonary embolism pe disease.

There are no international standards for ddimer and different assays use antibodies with differing specificities for ddimer and other fibrin degradation products. An elevated concentration of ddimer is often suggestive of secondary fibrinolytic hyperthyroidism. Disseminated intravascular coagulation dic in dic the fibrinolytic system is activated and therefore the ddimer level increases. Sampling center sample and all axsym d dimer reagents required for one test are pipetted by the sampling probe into various wells of a reaction vessel rv. Ddimer test has been standardized using a purified. This can lead to poor correlation between methods reporting results in ddu. Reagent preparation manual test procedure allow all vials to. St1500 indication ddimer test kit ddimer control kit kit size 16 testskit 2 x 1 ml high and low summary. The ddimer assay of the plasmas to be tested is automatically carried out by the.

Please use the form below to provide feedback related to the content on this. Axsym d dimer is based on microparticle enzyme immunoassay meia technology. Ddimer methods, informing them of the confusion regarding the type and magnitude of ddimer units and the common practice by laboratories of converting the units. From june 2011, this document is the only relevant source for assay application information on the sysmex ca500 series system. Package insert instructions must be followed accordingly.

Ddimer results are critical to the diagnostic algorithm for the exclusion of vte in low and moderate pretest probability patients and their use is guided by clsi document h59a. This can lead to poor correlation between methods reporting results in d du. Manual for a complete description of the quality control system. Evolution of the ddimer assay in clinical medicine monet n. Ddimer level is a useful tool for the evaluation of risk of vte recurrence in such patients 12, 14, 17, 18.

Pdf widespread use of ddimer in recent years has led to the development of a number of new fully automated quantitative ddimer assays. Offers 99% npv for all patients even those presenting with medium risk for the most serious condition, pulmonary embolism. Learn about the test, when you would need one, and what the results can tell you. Through this activation, fibrin is degraded by plasmin to various soluble fragments in which the ddimer configuration occurs. Instrumentation laboratory company, bedford, ma 22017. Access important information about chemistry reagents and immunosuppressant drug monitoring assays, including application sheets, package inserts, safety data sheets, and videos. Please contact your beckman coulter account representative for more information. Qdl97000bd bonus pack 25 x 3, 1 kit of each test triage cardiac panelbnp, d dimer combo 3 kits, 25 tests per kit one of bnp. The types of immunoassays available for ddimer measurement include. It aims to better serve our customers while helping to preserve the planet.

Blood should be collected in a bluetop tube containing 3. Hemosil reagents instrumentation laboratory worldwide. Ddimer is elevated in several clinical conditions including dvt, pe and disseminated intra vascular coagulation dic. Vidas d dimer exclusion ii features d dimer exclusion in a single test. Triage ddimer test 7 standardization the quidel triage ddimer test has been standardized using a puri. Reagents that require calibration are described in the reagent package insert. The innovance ddimer is substantially equivalent to the vidas ddimer exclusiontm k040882 assay. Vidas ddimer exclusion ii is the first test indicated for use to safely exclude a diagnosis of dvt and pe in outpatients with suspected vte, in conjunction with a clinical pretest probability ptp assessment model. Nanopia pfdp blood coagulation diagnostics business.

These products are intended for use in the united states only. The alere triage ddimer test is a fluorescence immunoassay to be used. This package insert must be read carefully prior to use. Evaluation of the alere ddimer test for point of care testing article in journal of thrombosis and thrombolysis 382 august 2014 with 623 reads how we measure reads. Key to symbols used list number calibrator a lot number calibrator b in vitro diagnostic medical device. Ddimer is a coagulation marker that reflects the degree of thrombin turnover. Alere triage meterpro ddimer method and sample collection iecdd. Total fdp is always higher than the ddimer value when using nanopia ddimer. Stago ddimer for the exclusion of thromboembolism diet. Package insert ddimer fs english diasys diagnostic systems. Alere triage ddimer test product insert pi, english quidel. Hemosil ddimer assays are clinically validated with cutoff values for the exclusion of venous thromboembolism vte, including both pulmonary embolism pe and deep vein thrombosis dvt, in conjunction with a pretest probability assessment. Ddimer refer to or the package insert of currently available lots for specific analyte and stability claims.

Ddimer for exclusion of venous 0918 9311554010gbc this document is not legally binding. Use the reagent code chip module supplied with the new lot of test devices to transfer the data to the meter. The ddimer rapid test cassette whole bloodplasma is a rapid chromatographic immunoassay for the qualitative detection of human d dimer in whole blood or plasma as an aid. This approach can reduce the need for costly and invasive imaging tests, typical in the diagnosis of vte. During early clot formation, thrombin cleaves fibrinopeptides from the fibrinogen, a soluble plasma protein, converting it into fibrin monomers. Evaluation of the alere ddimer test for point of care testing. Purpose and scope the purpose of this document is to describe the procedure for performing a ddimer.

In an exclusion strategy, a ddimer below the established threshold in a. Ddimer assays can help in the diagnosis of dic, and in dic patients management 5, 8, 14, 18. The ddimer test is a quick way to check if you might have a serious blood clot. Ddimer latex agglutination kit diagnostic reagent for the rapid qualitative or semiquantitative evaluation of circulating derivates of crosslinked fibrin degradation products xlfdp in human plasma t9515707 1 x 2,7 ml ddimer latex 1 x 25 ml ddimer buffer 1 x 0,5 ml positive control 1 x 0,5 ml negative control 5 pcs. This package insert must be read carefully prior to product use.

First d dimer test cleared by the fda for exclusion of pe and dvt. The alere triage ddimer test utilizes the 3b6 monoclonal antibody which is highly specific to crosslinked ddimer. All of the ddimer assays currently available incorporate antibody recognition of and binding to the ddimer molecules. My name is laura worfolk and i am the scientific and clinical research manager for diagnostica stago. Staliatest ddi plus, less interferences for even more confidence back to list as part of stagos continuous improvement commitment, sta liatest ddi plus was developed as an evolution of the sta liatest ddi, one of the most published ddimer assays, also fda approved for aid in the diagnosis of venous thromboembolism vte. Clinical application of the innovance ddimer assay in the. The stratus cs ddimer assay is intended for use in conjunction with a nonhigh clinical pretest probability ptp assessment model to. D dimer is elevated in several clinical conditions including dvt, pe and disseminated intra vascular coagulation dic. The eurolyser ddimer test allows quick and easy determination of the parameter at the point of care.

The adverse drug reactions reported included headache, pain in the extremities, pain at the injection site, and increase in fibrin d dimer levels without evidence of thromboembolic events. Insert the test device into the test slot of the analyzer. Clinical utility of sta liatest ddimer laura worfolk. The imuclone ddimer elisa is intended for the measurement of ddimer, crosslinked fibrin degradation product xlfdp, in human plasma.

D dimer is a specific marker of degradation of fibrin clot and an indirect marker of clot formation. Ddimer determination is mainly used to exclude deep vein thrombosis of the leg and pulmonary embolism. It is left to the individual laboratory to define ddimer cut off values for use in the isth scoring system. Vidas ddimer exclusion iidex2 vidas ddimer exclusion ii is an automated quantitative test for use on the instruments of the vidas family for the immunoenzymatic determination of fibrin degradation products fbdp in human plasma sodium citrate using the elfa technique enzyme linked fluorescent assay. Proper storage and use of products in compliance with the operator manual package inserts and with diagnostica stago, inc.

657 1168 1533 541 1640 810 857 1202 1606 1671 807 371 1630 270 1479 256 1234 787 1482 1352 447 669 1339 536 985 280 422 241 1165 837 237 833 1593 765 426 1493 48 552 226 897 45 364